Search results for " Minimally invasive surgical procedures"
showing 10 items of 11 documents
Risk of Virus Contamination Through Surgical Smoke During Minimally Invasive Surgery: A Systematic Review of the Literature on a Neglected Issue Revi…
2020
Abstract Context The coronavirus disease 2019 (COVID-19) pandemic raised concerns about the safety of laparoscopy due to the risk of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) diffusion in surgical smoke. Although no case of SARS-CoV-2 contagion related to surgical smoke has been reported, several international surgical societies recommended caution or even discouraged the use of a laparoscopic approach. Objective To evaluate the risk of virus spread due to surgical smoke during surgical procedures. Evidence acquisition We searched PubMed and Scopus for eligible studies, including clinical and preclinical studies assessing the presence of any virus in the surgical smoke fr…
Is Transcranial Magnetic Resonance Imaging-Guided Focused Ultrasound a Repeatable Treatment Option? Case Report of a Retreated Patient With Tremor Co…
2019
Introduction In recent years, transcranial Magnetic Resonance Imaging-guided Focused Ultrasound (tcMRgFUS) treatments for functional neurological disorders are giving a new thrust to the field of therapeutic brain lesioning. Objective To present the case of a patient affected by tremor combined with Parkinsonism who underwent a second tcMRgFUS thalamotomy because of relapsing tremor after a few months from the first tcMRgFUS treatment. Methods A 72-yr-old, right-handed man, came to our observation because of a disabling tremor affecting his upper limbs, refusing any invasive surgical procedure and already treated by tcMRgFUS left Vim thalamotomy. However, clinical benefit had brief duration…
Customized approach for otogenic brain abscess: the neurosurgical prospective.
2017
Clinical analysis following lumbar interspinous devices implant: where we are and where we go
2014
Objectives:We present our experience with patients treated with interspinous devices who are affected by neurogenic intermittent claudication (NIC) or lumbar disc herniation (LDH) where the interspinous system has been inserted following microdiscectomy.Study design:Retrospective study.Methods:This study included patients (n=100) with NIC secondary to lumbar spinal stenosis (group 1), and patients (n=100) with LDH (group 2) in whom the interspinous device has been implanted following radicular decompression in a period spanning 6 years. The latter have been compared with a homogenous group of patients (n=100) where no interspinous system has been implanted following microdiscectomy (group 3…
Chirurgia trans-cranica mediante ultrasuoni focalizzati ad alta intensità su guida RM: esperienza preliminare a 1,5T
2015
Da qualche anno la chirurgia mediante ultrasuoni focalizzati ad alta intensità guidati da Risonanza Magnetica (Magnetic Resonance guided Focused Ultrasound Surgery, MRgFUS) si sta diffondendo anche in Italia per la palliazione del dolore da metastasi ossee, per il trattamento di tumori ossei primitivi (benigni e non), dei fibromi e dell’adenomiosi uterina; sono già stati inoltre pubblicati i risultati preliminari del trattamento di alcuni tumori epatici, pancreatici, prostatici e della mammella mediante MRgFUS. Questa innovativa tecnica prevede l’utilizzo di un’apparecchiatura di Risonanza Magnetica per il monitoraggio della procedura e sfrutta le caratteristiche fisico- meccaniche degli …
Transcranial magnetic resonance-guided focused ultrasound surgery at 1.5T: a technical note.
2019
Magnetic resonance-guided focused ultrasound is one of the emerging non-invasive technologies offering both image guidance and thermal monitoring. In recent years transcranial application of this technology is starting to impact heavily the neuroscience field. We present here the imaging protocol and the technological methods successfully used with a transcranial magnetic resonance-guided focused ultrasound system certified for clinical treatments of functional neurological disorders, integrated for the first time with a 1.5T magnetic resonance scanner. Compared to the body radiofrequency coil (the one commonly used with transcranial magnetic resonance-guided focused ultrasound system integ…
Robotic versus laparoscopic surgery in gynecology: Which should we use?
2015
This review of the literature aims at assessing the safety and effectiveness of robotic versus laparoscopic surgery in benign and malignant gynecological diseases. Robotic-assisted laparoscopy is already widely used in the United States and Europe for the main gynecological procedure - hysterectomy - and has proved feasible and comfortable for other benign and malignant gynecological procedures. However, the clinical effectiveness and safety of robotic surgery compared with standard laparoscopy have not been undoubtedly established. We reviewed the literature by searching in the Ovid/MEDLINE, PubMed, Cochrane Library, and Google Scholar databases for all the articles published from January …
MRgFUS results Italy
2017
PURPOSE: To present our preliminary results achieved with the first Italian installation of a trans-cranial MRI-guided Focused Ultrasound Surgery (tcMRgFUS) certified system for functional neurosurgery. Moreover, to our knowledge, this is the world-first tcMRgFUS system ever installed on a 1.5T MRI unit. Technical issues faced to achieve a safe and effective treatment will be discussed focusing on MR high-resolution live imaging and thermometry sequences optimization. METHOD AND MATERIALS: Patient enrollment was based on indication for functional neurosurgery and evidence of medication-refractory disease; a detailed medical history has been collected together with a complete clinical examin…
Minimally invasive secondary cytoreduction plus HIPEC for recurrent ovarian cancer: a case series.
2014
Objective To analyze the feasibility of laparoscopic/robotic secondary cytoreductive surgery and hyperthermic intraperitoneal intra-operative chemotherapy (SCS + HIPEC) in a retrospective series of isolated platinum sensitive recurrent ovarian cancer. Methods We retrospectively evaluated a consecutive series of ovarian cancer patients with isolated platinum sensitive relapse. Isolated relapse was defined as the presence of a single nodule, in a single anatomic site. In all cases the presence of isolated relapse was assessed at pre-operative FDG-PET/CT scan, and confirmed with staging laparoscopy performed immediately before SCS + HIPEC. Results 84 women with platinum sensitive relapse recei…
What Is the Role of Minimally Invasive Mitral Valve Surgery in High-Risk Patients? A Meta-Analysis of Observational Studies
2016
Background. Minimally invasive valve surgery is related to certain better postoperative outcomes. We aimed to assess the role of minimally invasive mitral valve surgery in high-risk patients. Methods. A systematic literature review identified eight studies of which seven fulfilled criteria for metaanalysis. Outcomes for a total of 1,254 patients (731 were conventional standard sternotomy and 523 were minimally invasive mitral valve surgery) were submitted to meta-analysis using random effects modeling. Heterogeneity and subgroup analysis with quality scoring were assessed. The primary end point was early mortality. Secondary end points were intraoperative and postoperative outcomes and long…